Manufacturer: Macromatic Description: Enclosure; Protective Cover; Time Ranger-? III Relay; 1.89 in.; 1.76 in. UL Recognized and CSA Certified Features 8 Field-Selectable Functions: On Delay,
Flasher, Interval/Off Delay, Off Delay (2 Versions), Interval, Delayed Interval and On Delay/Off Delay Pushbutton Thumbwheels for Digital-Set LCD Display with Output Status and Percent of Time
Remaining Bar Specifications 24-240 VAC/12-240 VDC Input Voltage 0.1 Sec. to 9,990 Hr. Timing Range SPDT 3 A @ 250 VAC Repeat Accuracy: ±0.3% Temperature: –10° to 55°C Dimensions: 1.9" × 1.9" ×
3.5"
Manufacturer: Macromatic Description: Relay; 1 to 10 A; 120 VAC; SPDT 8 Pin Plug-In; LED; cULus Recognized, UL Listed Current Monitor Relays monitor AC single-phase currents for over or under
current conditions. A separate 120 VAC input (supply) voltage is required to power these units. Three current ranges are available: 0.1-1 A; 0.5-5 A; and 1-10 A. An external current transformer may
be used to extend the range of these products. The drop-out current setting is adjustable from 50-95% of the selected pick-up setting. The relay will energize when the monitored AC current is above
the pick-up setting, and will de-energize when the monitored AC current is below the drop-out setting. Features Monitors AC Single Phase Currents Three Separate Current Monitoring Ranges Covering
0.1-10 Amperes External CT Can Be Used to Extend Ranges Standard 8-Pin SPDT Octal Socket Mounting Specifications SPDT 10 A @ 240 VAC/30 VDC Dimensions: 1.7" × 2.4" × 3.5" Temperature: –28°C to 55°C
Manufacturer: Macromatic Description: Relay; 0.5 to 5 A; 120 VAC; SPDT 8 Pin Plug-In; LED Current Monitor Relays monitor AC single-phase currents for over or under current conditions. A separate
120 VAC input (supply) voltage is required to power these units. Three current ranges are available: 0.1-1 A; 0.5-5 A; and 1-10 A. An external current transformer may be used to extend the range of
these products. The drop-out current setting is adjustable from 50-95% of the selected pick-up setting. The relay will energize when the monitored AC current is above the pick-up setting, and will
de-energize when the monitored AC current is below the drop-out setting. Features Monitors AC Single Phase Currents Three Separate Current Monitoring Ranges Covering 0.1-10 Amperes External CT Can
Be Used to Extend Ranges Standard 8-Pin SPDT Octal Socket Mounting Specifications SPDT 10 A @ 240 VAC/30 VDC Dimensions: 1.7" × 2.4" × 3.5" Temperature: –28°C to 55°C